LOW NOx HOT WATER BOILERS
Parker Hot Water Boilers are designed specifically to provide the building heating and industrial processing industries
UP TO 6,300,000 BTU (ATMOSPHERIC AVAILABLE)
VIEW ATMOSPHERIC MODELS
ATMOSPHERIC AVAILABLE
ATMOSPHERIC MODELS
Never A Compromise
For Quality or Safety
T he Parker Boiler System consists of a burner bed of Heavy Duty Metal Fiber Burners (MFB). Through a gas/air premix manifold, the burners may be linked to a fully modulating blower mixer which offers precise control of combustion through the full range of modulation.
Low NOx L-Models and Internal Heat Reclaimer LR-Models
Boilers up to 6,300,000 BTU
Parker Hot Water Boilers are designed specifically to provide the building heating and industrial processing industries with a Superior Quality Boiler with Unequaled Advantages in Safety, Long Life Service and Economical Operation.
Low NOx Hot Water Boiler Certifications ("L" Model)
All boilers are built in accordance with the ASME Power and Heating Boiler Code. All boilers are inspect-ed and registered with the National Board of Pressure Vessel Inspectors. All individual gas and electrical controls are AGA certified or UL Listed. All models are ETL Listed as “Industrial and Commercial Gas Fired Packaged Boilers” and certified to UL795. All units are provided with trim and controls to meet ASME CSD-1 standards for “Controls & Safety Devices for Automatically Fired Boilers.” In addition, all units also meet the standards of the International Conference of Building Officials, International Association of Mechanical & Plumbing Officials and the Uniform Mechanical Code.
Low NOx Hot Water Boiler w/ Internal Reclaimer Certifications ("LR" Model)
All Parker Boiler Hot Water Boilers are built in accordance with the ASME Power and Heating Boiler Code. All boilers are inspected and registered with the National Board of Pressure Vessel Inspectors. All individual gas and electrical controls are AGA certified or UL Listed. All models are ETL Listed as “Indus-trial and Commercial Gas Fired Packaged Boilers” and certified to UL795. All units are provided with trim and controls to meet ASME CSD-1 standards for “Controls & Safety Devices for Automatically Fired Boilers.” In addition, all units also meet the standards of the International Conference of Building Officials, International Association of Mechanical & Plumbing Officials and the Uniform Mechanical Code.
Safety Our ASME tube bundle is extremely flexible and offers a long life with a 25 year warranty against thermal shock. No Parker Boiler has ever been known to experience an internal explosion.
Advantages (Low NOx and Internal Reclaimer Models)
Safety
Large Heating Surface
Simplicity
Efficiency
Built-In Finned Tubes ("LR" Model only)
Low NOx
VFD/Premix System
Low Cost Operation
Efficient Operation
Fast Heat-Up
Accessible Internal Inspection
Ease of Inspection and Repair
Codes
Heavy Duty Tubes
Heavy Insulated Cabinet
Low NOx Premix Direct Fired Hot Water Boiler Bent Steel Water Tube Parker "L" Models 300,000 to 6,800,000 BTU Gas Fired
Parker Boiler Premix Burner System
The Parker Boiler System consists of a burner bed of Heavy Duty Metal Fiber Burners (MFB). Through a gas/air premix manifold, the burners may be linked to a fully modulating blower mixer which offers precise control of combustion through the full range of modulation. Parker Boiler uses a variety of premix gas/air mixing & delivery systems for it's "L" System boilers. Parker Boiler's Low NOx Systems are typically designed for a 20 or 30 ppm level at 3% O2, however, special lower Low NOx boilers are available.In all cases, a Premixed gas/air is distributed to the burners by a manifold. By precisely controlling the gas/air ratio provided to the burners, Low NOx emission & efficient clean combustion is obtained.
Parker Boiler Premix Burner System 4 Variable Speed Drive Fan Post Mix System Siemens SKP - Controller
Parker Boiler Premix Burner System 5 Variable Speed Drive Fan Post Mix System Honeywell Valve/Venturi
Low NOx Hot Water Boiler Insert ("L" Model)
Low NOx High Efficiency Premix Direct Fired Hot Water Boiler Bent Steel Water Tube Parker Boiler "LR" Model 300,000 to 6,300,000 BTU Premix Gas Fired
Low NOx Hot Water Boiler With Internal Reclaimer Insert ("LR" Model)
Unlike Conventional Power Burner Technology, the burner bed provides a uniform heat distribution on all boiler tubes for improved heat transfer and boiler efficiency. Uniform heat over the entire heating surface at high, low and modulating firing rates provides longer tube life by eliminating concentrated firing on limited tube surface.
High Efficiency “LR” models incorporate a built in finned steel tube bundle in addition to the standard tubes. These heavy duty finned tubes are placed above the standard Parker Boiler tubes, and they significantly increase the amount of heat absorbed from the flue gases, thus increasing boiler efficiency. With the additional heating surface, the already long Parker Boiler Hot Water Boiler life is extended even further. The efficiency ranges from 83 to 85%.
NOTE: All drawing dimensions should be verified prior to installation. Due to continuous improvements and irregularities of purchased structural shapes and rounding, dimensions may vary and are subject to change without notice.If the model of the boiler you are looking for is not readily available here please contact Parker Boiler for more assistance at (323) 727-9800 from 8:00AM to 5:00PM (PST).