Never A Compromise For Quality or Safety
The Parker Indirect Fired Water Heater is an industrial quality unit designed for economically heating large volumes of domestic or process water for commercial and industrial applications. The all bronze and copper heat transfer coil eliminates the possibility of rust throughout the water passages. The indirect principle of heating the process water with sealed-in primary water combined with controlled circulation minimizes the possibility of scaling within the heat transfer coil for low or high temperature applications.
Heaters up to 3,000,000 BTU
The Parker WH Model Indirect Fired Water Heater is an excellent choice for Low or High Temperature applications.
Atmospheric Hot Water Heater Certifications
All Parker Boiler Water Heaters are manufactured in accordance with the ASME Power & Heating Boiler Codes and registered with the National Board of Boiler and Pressure Vessel Inspectors. The standard natural gas fired model is furnished as an Underwriters Laboratories, Inc. Listed Gas Fired Boiler Assembly and displays this symbol on the nameplate. Outdoor, propane and Low NOx models are ETL listed. Canadian models are C-ETL Listed Industrial and Commercial Gas Fired Packaged Boilers certified to CAN/CGA 1-3.1 and UL 795.
Low NOx Hot Water Heater Certifications
All Parker Boiler Water Heaters are manufactured in accordance with the ASME Power & Heating Boiler Codes and registered with the National Board of Boiler and Pressure Vessel Inspectors. All individual gas and electrical controls are AGA certified or UL Listed. All models are ETL Listed as "Industrial and Commercial Gas Fired Packaged Boilers" and certified to UL795. Units are listed for potable water. All units are provided with trim and controls to meet ASME CSD-1 standards for "Controls & Safety Devices.
Safety
Our ASME tube bundle is extremely flexible and offers a long life with a 25 year warranty against thermal shock. No Parker Boiler has ever been known to experience an internal explosion.
Advantages (Low NOx Models Included)
- Safety
- Heat Transfer Coil
- Simplicity
- Efficiency
- Uniform Heat Distribution
- Low NOx
- VFD/Premix System
- Durable Low NOx Burners
- Increased Life
- Reduced Repair Cost
- Stainless Steel Option
- Staggered Tube Design
- Codes
- Heavy Duty Tubes
- Heavy Insulated Cabinet
Indirect Fired Water Heater
Indirect Fired Hot Water Heater
Natural Thermal Circulating
300,000 to 3,000,000 BTU Gas Fired
Indirect Heating Principle & Diagram
The Basic Principle of indirect heating is accomplished by circulating the low temperature or circulating processed water through a copper tube heat transfer coil which is mounted internally and immersed in the primary Boiler water. The primary Boiler water is contained in a Bent Steel Tube Bundle and is heated in the furnace area, it rises to the upper header where the heat transfer into the secondary water occurs. The colder secondary water does not come into contact with high furnace temperatures or into contact with the flue gas at all. This eliminates any possibility of flue gas condensation which will occur on Direct Fired Heaters. Sweating and external corrosion of the Boiler Structure and tubes is essentially eliminated. The possibilities of scale, rust and corrosion are minimized by the indirect design principle. The furnace remains at a steady uniform temperature which results in high combustion efficiency and lower fuel consumption. This principle has proven more efficient and provides for a longer life as opposed to a direct system.
- Laundries
- Hotels
- Apartments
- Dairies
- Food Processing
- Hospitals
- Schools
- Swimming Pools
- Water Source Heat Pumps
- Low Temperature Process Water Applications
- Pond Heating
- Fish Farms
- Radiant Heating
- Nurseries
Indirect Fired Water Heater (Internal View)
Low NOx Premix
Indirect Fired Hot Water Heater
Natural Thermal Circulating
300,000 to 3,000,000 BTU Natural Gas or Propane Fired
Parker Boiler Premix Burner System
The Parker Boiler System consists of a burner bed of Heavy Duty Metal Fiber Burners (MFB). Through a gas/air premix manifold, the burners may be linked to a fully modulating blower mixer which offers precise control of combustion through the full range of modulation. Parker Boiler uses a variety of premix gas/air mixing & delivery systems for it's "L" System boilers. Parker Boiler's Low NOx Systems are typically designed for a 20 or 30 ppm level at 3% O2, however, special lower Low NOx boilers are available. In all cases, a Premixed gas/air is distributed to the burners by a manifold. By precisely controlling the gas/air ratio provided to the burners, Low NOx emission & efficient clean combustion is obtained.
Parker Boiler Premix Burner System 4
Variable Speed Drive Fan Post Mix System
Siemens SKP - Controller
Parker Boiler Premix Burner System 5
Variable Speed Drive Fan Post Mix System
Honeywell Valve/Venturi
Low NOx Hot Water Heater Insert (Internal View)
Title | Categories | Update Date | Download |
---|---|---|---|
Low NOx 1,210,000 BTU Anchor Clip Drawing (Model-WH1210L) 1 file(s) 52 downloads |
210L CAD AC | July 26, 2018 | Download |
Low NOx 1,410,000 BTU Anchor Clip Drawing (Model-WH1410L) 1 file(s) 43 downloads |
210L CAD AC | July 26, 2018 | Download |
Low NOx 1,900,000 BTU Anchor Clip Drawing (Model-WH1900L) 1 file(s) 71 downloads |
210L CAD AC | July 26, 2018 | Download |
Low NOx 300,000 BTU Anchor Clip Drawing (Model-WH300L) 1 file(s) 44 downloads |
210L CAD AC | July 26, 2018 | Download |
Low NOx 395,000 BTU Anchor Clip Drawing (Model-WH395L) 1 file(s) 46 downloads |
210L CAD AC | July 26, 2018 | Download |
Low NOx 490,000 BTU Anchor Clip Drawing (Model-WH490L) 1 file(s) 61 downloads |
210L CAD AC | July 26, 2018 | Download |
Low NOx 600,000 BTU Anchor Clip Drawing (Model-WH600L) 1 file(s) 44 downloads |
210L CAD AC | July 26, 2018 | Download |
Low NOx 970,000 BTU Anchor Clip Drawing (Model-WH970L) 1 file(s) 38 downloads |
210L CAD AC | July 26, 2018 | Download |
NOTE: All drawing dimensions should be verified prior to installation. Due to continuous improvements and irregularities of purchased structural shapes and rounding, dimensions may vary and are subject to change without notice. If the model of the boiler you are looking for is not readily available here please contact Parker Boiler for more assistance at (323) 727-9800 from 8:00AM to 5:00PM (PST).
Title | Categories | Update Date | Download |
---|---|---|---|
Hot Water Heater Atmospheric Brochure 1 file(s) 909 downloads |
210 Brochures, ENG - 209-11 | November 6, 2018 | Download |
Hot Water Heater Low NOx Brochure 1 file(s) 475 downloads |
210 Brochures, ENG - 209-11 | November 6, 2018 | Download |
Hot Water Heater System Brochure 1 file(s) 558 downloads |
210 Brochures, ENG - 209-11 | June 18, 2020 | Download |
Title | Categories | Update Date | Download |
---|---|---|---|
1,200,000-3,000,000 BTU Low NOx Hot Water Heater Spec Sheet (standard) 1 file(s) 781 downloads |
210 Spec Sheets, ENG - 209-11 | November 6, 2018 | Download |
300,000-3,000,000 BTU Atmospheric Hot Water Heater Spec Sheet (outdoor model) 1 file(s) 643 downloads |
210 Spec Sheets, ENG - 209-11 | November 6, 2018 | Download |
300,000-3,000,000 BTU Atmospheric Hot Water Heater Spec Sheet (standard) 1 file(s) 860 downloads |
210 Spec Sheets, ENG - 209-11 | November 6, 2018 | Download |
300,000-970,000 BTU Low NOx Hot Water Heater Spec Sheet (standard) 1 file(s) 577 downloads |
210 Spec Sheets, ENG - 209-11 | November 6, 2018 | Download |
Title | Categories | Update Date | Download |
---|---|---|---|
Hot Water Heater Atmospheric W/ Fireye Flame Safeguard Manual 1 file(s) 372 downloads |
210 Manuals | December 13, 2016 | Download |
Hot Water Heater Atmospheric W/ Honeywell S86 Flame Safeguard Manual 1 file(s) 360 downloads |
210 Manuals | December 13, 2016 | Download |
Hot Water Heater Low NOx W/ Fireye Safeguard Manual 1 file(s) 345 downloads |
210 Manuals | December 13, 2016 | Download |